Search results for "observer variation"

showing 10 items of 156 documents

Reproducibility and Daytime-Dependent Changes of Corneal Epithelial Thickness and Whole Corneal Thickness Measured With Fourier Domain Optical Cohere…

2016

To evaluate the reproducibility of Fourier domain anterior segment optical coherence tomography (RTVue) based on repeated measurements of corneal thickness (CT) and epithelial thickness (ET) and to test daytime-dependent changes of these parameters.Twenty-three eyes from 23 healthy volunteers were included in this prospective study. Three clinical observers performed 3 consecutive measurements each of CT and ET in 3 sessions using RTVue, resulting in 9 measurements per session. Session 1 was performed at 9 AM ± 1 hour, session 2 at 4 PM ± 1 hour on the same day, and session 3 at 9 AM ± 1 hour 2 days later. CT and ET were assessed in 9 areas: corneal vertex, 4 paracentral zones, and 4 periph…

AdultMaleDaytimeMaterials sciencegenetic structuresCornea03 medical and health sciences0302 clinical medicineOpticsOptical coherence tomographyCorneamedicineHumansProspective StudiesFourier domainObserver VariationReproducibilitymedicine.diagnostic_testbusiness.industryEpithelium CornealReproducibility of ResultsMiddle Agedeye diseasesOphthalmologymedicine.anatomical_structure030221 ophthalmology & optometryFemalesense organsObserver variationbusiness030217 neurology & neurosurgeryTomography Optical CoherenceBiomedical engineeringCornea
researchProduct

Early motor development and later language and reading skills in children at risk of familial dyslexia.

2005

Relationships between early motor development and language and reading skills were studied in 154 children, of whom 75 had familial risk of dyslexia (37 females, 38 males; at-risk group) and 79 constituted a control group (32 females, 47 males). Motor development was assessed by a structured parental questionnaire during the child's first year of life. Vocabulary and inflectional morphology skills were used as early indicators of language skills at 3 years 6 months and 5 years or 5 years 6 months of age, and reading speed was used as a later indicator of reading skills at 7 years of age. The same subgroups as in our earlier study (in which the cluster analysis was described) were used in th…

MaleVocabularyTime Factorsmedia_common.quotation_subjectGross motor skillSeverity of Illness IndexDevelopmental psychologyDyslexiaDevelopmental NeuroscienceRisk FactorsReading (process)Surveys and QuestionnairesSeverity of illnessmedicineHumansMass ScreeningChildMotor skillmedia_commonObserver VariationLanguage DisordersDyslexiamedicine.diseaseMotor Skills DisordersLanguage developmentReadingChild PreschoolPediatrics Perinatology and Child HealthFemaleNeurology (clinical)PsychologyReading skillsDevelopmental medicine and child neurology
researchProduct

Precision of a commercial hartmann-shack aberrometer: limits of total wavefront laser vision correction.

2012

Purpose To assess the intrasession and intersession precision of higher-order aberrations (HOAs) measured using a commercial Hartmann-Shack wavefront sensor (Zywave; Bausch & Lomb) in refractive surgery candidates. Design Prospective, experimental study of a device. Methods To analyze intrasession repeatability, 1 experienced examiner measured 30 healthy eyes 5 times successively. To study intersession reproducibility, the same clinician obtained measurements from another 30 eyes in 2 consecutive sessions at the same time of day 1 week apart. Results For intrasession repeatability, excellent intraclass correlation coefficients (ICCs) were obtained for total ocular aberrations, total HOAs, a…

AdultMaleCorneal Wavefront AberrationIntraclass correlationZernike polynomialsmedicine.medical_treatmentRefraction Ocularsymbols.namesakeYoung AdultOpticsRefractive surgeryAberrometrymedicineHumansProspective StudiesMathematicsWavefrontObserver VariationReproducibilitybusiness.industryAberrometryReproducibility of ResultsRepeatabilityWavefront sensorMiddle AgedRefractive ErrorsOphthalmologysymbolsOptometryFemalebusinessAmerican journal of ophthalmology
researchProduct

Quantitative corneal anatomy in emmetropic subjects.

2006

PURPOSE Currently there is little information available about the corneal thickness values of healthy emmetropic subjects. Therefore, the authors decided to analyze the corneal thickness in healthy emmetropic subjects. METHODS The authors analyzed the difference in thickness values between the thinnest corneal site and the central and paracentral cornea in 124 eyes of 124 healthy emmetropic white subjects. RESULTS The mean difference between the thinnest site of the cornea and the thickness values obtained in the areas analyzed was as follows: 12+/-6 microm center; 140+/-19 microm superonasal; 133+/-23 microm nasal; 117+/-26 microm inferonasal; 122+/-19 microm superotemporal ; 89+/-22 micro…

Adultgenetic structuresAdolescentEmmetropiaMean differenceCornea03 medical and health sciences0302 clinical medicineReference ValuesCorneamedicineHumansProspective StudiesUltrasonographyObserver VariationAnthropometrybusiness.industryGeneral MedicineAnatomyeye diseasesOphthalmologymedicine.anatomical_structureReference values030221 ophthalmology & optometrysense organsUltrasonographyObserver variationbusiness030217 neurology & neurosurgeryEuropean journal of ophthalmology
researchProduct

Cephalometric measurements from 3D reconstructed images compared with conventional 2D images

2011

Abstract Objective: To assess whether the values of different measurements taken on three-dimensional (3D) reconstructions from cone-beam computed tomography (CBCT) are comparable with those taken on two-dimensional (2D) images from conventional lateral cephalometric radiographs (LCRs) and to examine if there are differences between the different types of CBCT software when taking those measurements. Material and Methods: Eight patients were selected who had both an LRC and a CBCT. The 3D reconstructions of each patient in the CBCT were evaluated using two different software packages, NemoCeph 3D and InVivo5. An observer took 10 angular and 3 linear measurements on each of the three types o…

AdultMale2d imagesAdolescentCephalometryRadiographyDentistryOrthodonticsComputed tomographyImage processingMandibleYoung AdultImaging Three-DimensionalImage Processing Computer-AssistedMaxillamedicineHumansNasal BoneSella TurcicaChildMathematicsObserver VariationOrthodonticsmedicine.diagnostic_testPalatebusiness.industryIntraobserver reliabilityReproducibility of ResultsOriginal ArticlesCone-Beam Computed TomographyIncisorFaceMandibular planeFemalebusinessObserver variationSoftwareThe Angle Orthodontist
researchProduct

The effectiveness of a novel optical probe in subgingival calculus detection

2008

:  Objectives:  The aim of the present study was to evaluate the effectiveness of a novel optical calculus detection system under in vivo conditions. Methods:  One hundred and seventy-six tooth surfaces from 44 adult teeth that were indicated for extraction were selected for the present study. The patients were randomly assigned to one of the two experimental groups. In group A (n = 96), clinical presence or absence of subgingival calculus deposits was determined using the light-emitting diode-based optical probe (OP). In group B (n = 80), the subgingival deposits were first recorded with the OP followed by root surface debridement until no subgingival deposits could be detected by the devi…

AdultMaleRoot surfaceLightmedicine.medical_treatmentDentistryTooth rootScaling and root planingStereo microscopemedicineHumansDental CalculusDentistry (miscellaneous)Diagnosis Computer-AssistedObserver Variationbusiness.industryCalculus (dental)Subgingival calculusSignal Processing Computer-AssistedMiddle Agedmedicine.diseasestomatognathic diseasesSemiconductorsDebridement (dental)FemalebusinessObserver variationInternational Journal of Dental Hygiene
researchProduct

Reproducibility of grading systems in oral epithelial dysplasia

2012

Objective: To assess inter and intra observer variability in grading oral epithelial dysplasia (OED) using Smith and Pindborg grading system, WHO classification system and Brothwell DJ et al. classification system. Study design: In the study 45 histological tissues of dysplasia, 15 each of mild, moderate and severe dysplasia were coded and blindly graded by three observers in three grading systems. Further on the same observers graded 15 slides again of the previous 45 for analyzing the reproducibility in the three grading systems. The individual significance of various indicators of dysplasia among various grades of dysplasia was also assessed. Result: Inter observer agreement was signific…

Epithelial dysplasiamedicine.medical_specialtyPathologyInter observer agreementOdontologíaOral Medicine and PathologEpitheliummedicineHumansGrading (education)General DentistryObserver VariationNeoplasm GradingReproducibilitybusiness.industryMouth MucosaReproducibility of Resultsmedicine.disease:CIENCIAS MÉDICAS [UNESCO]Intra observerCiencias de la saludOtorhinolaryngologyDysplasiaUNESCO::CIENCIAS MÉDICASResearch-ArticleSurgeryRadiologyNeoplasm GradingbusinessWho classificationPrecancerous Conditions
researchProduct

Echocardiographic reference ranges for normal left ventricular 2D strain: results from the EACVI NORRE study

2017

International audience; Aims - To obtain the normal ranges for 2D echocardiographic (2DE) measurements of left ventricular (LV) strain from a large group of healthy volunteers accounting for age and gender. Methods and results - A total of 549 (mean age: 45.6 ± 13.3 years) healthy subjects were enrolled at 22 collaborating institutions of the Normal Reference Ranges for Echocardiography (NORRE) study. 2DE data sets have been analysed with a vendor-independent software package allowing homogeneous measurements irrespective of the echocardiographic equipment used to acquire the data sets. The lowest expected values of LV strains and twist calculated as ± 1.96 standard deviations from the mean…

MaleLongitudinal straindeformation imaging[SDV]Life Sciences [q-bio]Sex Factor030204 cardiovascular system & hematologyStandard deviationVentricular Function LeftHeart Ventricle2D echocardiography0302 clinical medicineReference ValuesNuclear Medicine and ImagingImage Processing Computer-AssistedMedicineCircumferential strainAge FactorReference Value030212 general & internal medicineMultivariate Analysi2D echocardiography; Adult echocardiography; Deformation imaging; Reference values; Radiology Nuclear Medicine and Imaging; Cardiology and Cardiovascular MedicineObserver VariationStrain (chemistry)Age FactorsGeneral MedicineMiddle AgedHealthy VolunteerHealthy VolunteersEuropeHomogeneousEchocardiographyRadiology Nuclear Medicine and imagingCardiologyLinear ModelFemaleRadiologyCardiology and Cardiovascular MedicineRadial stressHumanAdultmedicine.medical_specialtyadult echocardiographyHeart Ventricles03 medical and health sciencesSex FactorsInternal medicineHumansRadiology Nuclear Medicine and imaging2d strainbusiness.industryMED/11 - MALATTIE DELL'APPARATO CARDIOVASCOLAREReference valuesMultivariate AnalysisLinear Modelsbusiness
researchProduct

The learning curve, accuracy, and interobserver agreement of endoscope-based confocal laser endomicroscopy for the differentiation of colorectal lesi…

2012

Background: The endoscope-based confocal laser endomicroscopy (eCLE) system allows in vivo imaging of colorectal epithelium. Little is known about the learning curve for accurate interpretation of confocal images acquired with eCLE. Objective: To determine the learning curve of eCLE, its diagnostic accuracy, and the intra- and interobserver agreement for the differentiation of colorectal lesions. Design: Post hoc assessment of selected eCLE images. Setting: Academic centers. Patients: This study involved colonoscopic images from 47 patients. Main Outcome Measurements: Learning curve of eCLE, accuracy, and intraobserver and interobserver agreement. Methods: Three endoscopists received a shor…

AdenomaMalePathologymedicine.medical_specialtyendocrine systemFuture studiesObserver (quantum physics)EndoscopePost hocConfocalColonic PolypsSensitivity and SpecificitymedicineHumansRadiology Nuclear Medicine and imagingStage (cooking)AgedConfocal laser endomicroscopyObserver VariationChi-Square DistributionMicroscopy Confocalbusiness.industryCarcinomaGastroenterologyReproducibility of ResultsColonoscopyMiddle AgedLearning curveColitis UlcerativeFemalebusinessNuclear medicineColorectal NeoplasmsLearning CurveGastrointestinal endoscopy
researchProduct

Differences between orthopaedic evaluation and radiological reports of conventional radiographs in patients with minor trauma admitted to the emergen…

2017

Abstract Introduction During night and on weekends, in our emergency department there is no radiologist on duty or on call: thus, X-ray examinations (XR) are evaluated by the orthopaedic surgeon on duty and reported the following morning/monday by radiologists. The aim of our study was to examine the discrepancy rate between orthopaedists and radiologists in the interpretation of imaging examinations performed on patients in our tertiary level orthopaedic institution and the consequences of delayed diagnosis in terms of patient management and therapeutic strategy. Materials and methods We retrospectively reviewed all cases of discrepancy between orthopaedists and radiologists, which were ca…

AdultMalemedicine.medical_specialtyAdolescentElbowSensitivity and Specificity030218 nuclear medicine & medical imagingFractures BoneYoung Adult03 medical and health sciencesProfessional Competence0302 clinical medicinemedicineChi-square testHumansIn patientDiagnostic ErrorsChildAgedRetrospective StudiesGeneral Environmental ScienceAged 80 and overObserver Variationbusiness.industryGeneral surgery030208 emergency & critical care medicineEmergency departmentMiddle AgedSurgeryRadiographyOrthopedicsmedicine.anatomical_structureLower ExtremityMinor traumaChild PreschoolRadiological weaponOrthopedic surgeryGeneral Earth and Planetary SciencesFemaleAnkleEmergency Service HospitalbusinessInjury
researchProduct